DOCTOR 4 SURGICALS
Orthopedic Implants & Instruments
Diagnostic Equipments & Products
Anesthesia Equipments & Products
OB GYN (Gynecological) Products
Infant Care & Baby Care Equipments
+91 9751725000, +91 9751625000, +91 9751425000
d4scoin@gmail.com, kisusy.com@gmail.com, kirangroup108@gmail.com
AUTOCLAVE VERTICAL TYPE
( Model No. KSS 001 )
Full Stainless Steel Body welded by Argon Arc Process
Separate Air and condensate vents are provided to ensure that air / condensate is removed from the chamberthat airto facilitate through penetration of the load by st::-
Water outlet is provided to drain water from chamber preventing scale formation.
SpringloadedSafetyValvesareprovidedbothfortheinnerchamberaswell as for Tthe boiling chamber to prevent accidents.
Nuts, Bolts and Screws are made of Stainless Steel to prevent rusting.
Separate pressure gauge with spring loaded safetyvalve is provided forthe boiling chamber
F ITTINGS
Stainless Steel lid with heightening knobs
Water inlet cone, Steam control for inner chamber
Water level mark
Water inlet control
Pressure gauge for inner chamber
Adjustable pressure valve
Spring loaded safety valve for inner chamber
Pressure gauge for boiling chamber
Spring loaded safety valve for boiling chamber
Steam outlet
Water outlet
POWER SUPPLY
220 - 250 Volts
POWER CONSUMPTION
6kW(2x3kW)
AVAILABLE IN TWO SIZES
L6" x24" & 12" x 20"
The Inner and Outer chambers are made up with thick Steel of 304 / 3t6 grade and Jacket is made out of rolled Stainless Steel sheet with leak proof argon Arc welding. The radial locking lid
is made out of thick Stainless Steel Plate. All units are ydraulically tested up to 45 psi. The space between the outer chamber and steam jacket is fitted with asbestos steel / glass wool to minimize
thermal losses. Steam boiler is fitted with water level indicator, Pressure gauge, low water cut off device and automatic pressure control device. Fitted with a digital temperature indicator / analog meters to indicate inner temperature and vacuum breaker to break vacuum in case of formation of vacuum due to steam condensation. Two separate valves are provided for evacuating steam from inner chamber and jackets as and when desired sterilization cycle is controlled by MULTIPORT VALVE and the unit is fitted with all standard accessories such as Automatic pressure control switch, Automatic low water cut off device and Electronic sensor controlled system to work on 440 volts 3 phase supply.
HORIZONTAL MODELS
16x24 Cylindrical water cut off, pressure cut off anc
ectronc sensor controlled' Normal / High speed
15 x 48 Cylindrical all options, normal / high speed
20x48 Cylindrical all options, normal / high speed,
Single door /double door
2Ox2Ox48 Rectangular all options. Single door/Double door
24x24x48 Rectangular all options. Single door/Double door